easy-single-phase-ups-650i

Single Phase 650VA UPS

  • Microprocessor Control for High Reliability
  • Boost and Buck AVR to Stabilize Input Voltage
  • Supports DC start-up and auto restart

Specifications

PHASE 1-Phase Input / 1-Phase Output
MODEL EASY 650i
CAPACITY 650VA / 360W
Input Voltage Nominal 230V,  1p3w
INPUT Input Range 170 – 280V
Input Frequency 50 / 60 Hz
Output Voltage  220 / 230 / 240VAC
Voltage Regulation [Battery Mode] + / – 10%
Wave Form Modified Sine Wave
Frequency Range (Battery Mode) 50 / 60 Hz + / – 1 Hz
BATTERY Battery Type Maintenance free lead-acid batteries
Rated Battery Voltage 12VDC
Backup Time (@ Typical PC Load with 15” 10 – 15 mins
Monitor)
Recharge Time (to 90%) 6 hours
Battery Start  UPS can be started without AC source
TRANSFER TIME AC Mode ↔ Inverter Mode 2-6 ms typical, 10 ms max.
CONNECTIONS Input (1) IEC-320-C14
Output Receptacles (4) IEC-320-C13
CABLES Input Cable 1 x BS input cable
Output cable 1 x IEC output cable
DISPLAY Display Type LED
AC Mode Green LED Lit
Backup Mode Green LED Flashing
AUDIBLE ALARM Battery Mode Sounding every 10 seconds
Battery Low Sounding every 1 second
Overload Sounding every 0.5 second
Fault Continuous sounding
PROTECTION Full Protection Discharge, Over Charge & Overload Protection
DIMENSION Width x Height x Depth (mm) 100 x 143 x 278 mm
NETT WEIGHT 4.4 kg
ENVIRONMENT Audible Noise < 40 dBA
Temperature 0 to 40°C  ( 32 to 104°F)
Humidity 0% – 90% (Non-Condensing)
Altitude <1000 M Above Sea Level
COMMUNICATION USB USB on front panel
Download Single Phase 650VA UPS Brochure

easy-single-phase-ups-1200i

Single Phase 1200VA UPS

  • Microprocessor Control for High Reliability
  • Boost and Buck AVR to Stabilize Input Voltage
  • Supports DC start up and auto restart

Specifications

PHASE  1-Phase Input / 1-Phase Output 
MODEL  Easy 1200i 
CAPACITY  1200VA / 600W 
Input Voltage Nominal 230V,  1p3w
INPUT Input Range 170 – 280V
Input Frequency 50 / 60 Hz
Output Voltage  220 / 230 / 240VAC
Voltage Regulation [Battery Mode] + / – 10%
Wave Form Modified Sine Wave
Frequency Range (Battery Mode) 50 / 60 Hz + / – 1 Hz
BATTERY Battery Type Maintenance free lead-acid batteries
Rated Battery Voltage 24VDC
Backup Time (@ Typical PC Load with 15” 30 – 40 mins
Monitor)
Recharge Time (to 90%) 6 hours
Battery Start  UPS can be started without AC source
TRANSFER TIME AC Mode ↔ Inverter Mode 4-8 ms typical
DISPLAY Display Type LED
AC Mode Green LED Lit
Backup Mode Green LED Flashing
AUDIBLE ALARM Battery Mode Sounding every 10 seconds
Battery Low Sounding every 1 second
Overload Sounding every 0.5 second
Fault Continuous sounding
PROTECTION Full Protection Discharge, Over Charge & Overload Protection
DIMENSION Width x Height x Depth (mm) 139 x 195 x 365 mm
NETT WEIGHT 8.6 kg
ENVIRONMENT Audible Noise < 40 dBA
Temperature 0 to 40°C  ( 32 to 104°F)
Humidity 0% – 90% (Non-Condensing)
Altitude <1000 M Above Sea Level
COMMUNICATION USB Yes and RJ45
Download Single Phase 1200VA UPS Brochure